| Backward-Curved Fan | 1,000–300,000 m³/h | 500–4,000 Pa | 75–88% | High efficiency, stable operation, and relatively low power consumption. Non-overloading power characteristic helps protect the motor from excessive load. | Air-handling units, HVAC systems, clean-air ventilation, process air circulation, and large commercial buildings. | Check the required duty point, sound level, operating temperature, and whether the fan must handle clean or lightly contaminated air. | Energy-efficient systems |
| Airfoil Fan | 5,000–500,000 m³/h | 800–3,500 Pa | 80–90% | Very high aerodynamic efficiency and low noise when operating near the design point. Designed primarily for clean air. | Large HVAC installations, hospitals, airports, office buildings, data centers, and ventilation plants. | Not normally recommended for abrasive dust, fibrous material, sticky particles, or heavy particulate loading because the blade profile can foul. | High-volume clean air |
| Backward-Inclined Fan | 1,000–250,000 m³/h | 500–5,000 Pa | 70–85% | Good efficiency with a robust wheel design. Provides stable performance across a relatively broad operating range. | General industrial ventilation, dust collection pre-filtration, HVAC equipment, and manufacturing facilities. | Consider the expected dust concentration, abrasion risk, required pressure reserve, and the available installation space. | General industrial duty |
| Forward-Curved Fan | 500–80,000 m³/h | 100–2,000 Pa | 55–75% | Compact size, high airflow at low to medium pressure, and relatively low rotational speed, which can support quiet operation. | Fan-coil units, small air-handling units, packaged HVAC equipment, and light-duty ventilation. | Keep the fan near its intended operating point because the power curve can rise toward high airflow. Avoid heavily contaminated air unless specifically designed for it. | Compact HVAC equipment |
| Radial-Blade Fan | 500–100,000 m³/h | 1,000–10,000 Pa | 55–75% | Strong, simple blades tolerate dust, chips, fibers, and moderate deposits better than streamlined blade designs. | Dust collection, material handling, exhaust systems, industrial furnaces, and process ventilation. | Specify the particle size, bulk density, abrasiveness, gas temperature, and required wear protection. Balance the wheel carefully when handling solids. | Dirty or particulate air |
| Radial-Tip Fan | 1,000–150,000 m³/h | 1,500–8,000 Pa | 60–78% | Combines moderate efficiency with improved resistance to dust and abrasion compared with many high-efficiency clean-air wheels. | Industrial exhaust, moderate dust collection, process ventilation, and systems requiring medium to high pressure. | Evaluate abrasion protection, inlet conditions, fan speed, noise, and whether the transported material may build up on the wheel. | Industrial mixed-duty air |
| Plug or Plenum Fan | 2,000–300,000 m³/h | 300–2,500 Pa | 65–82% | Compact arrangement without a traditional scroll housing. Well suited to modular air-handling systems and variable-speed control. | Air-handling units, cleanrooms, data centers, tunnel ventilation modules, and retrofit systems with limited casing space. | Consider system leakage, discharge arrangement, inlet turbulence, service access, motor cooling, and whether a scroll housing is required for pressure recovery. | Space-saving air handlers |
| High-Pressure Industrial Fan | 500–60,000 m³/h | 5,000–20,000 Pa | 55–75% | Develops high static pressure for systems with long ducts, filters, heat exchangers, burners, or significant resistance. | Pneumatic conveying support, combustion air, industrial ovens, bag filters, scrubbers, and high-resistance process lines. | Confirm the complete system resistance at the required airflow, gas density, temperature, altitude, and motor starting requirements. | High-resistance systems |
| Multistage Centrifugal Fan | 100–20,000 m³/h | 10,000–50,000 Pa | 45–70% | Generates substantially higher pressure than a single-stage fan while maintaining a compact footprint for certain applications. | Boiler combustion air, wastewater aeration, pneumatic conveying, industrial drying, and process gas boosting. | Check gas temperature, pressure ratio, surge or unstable operating conditions, noise, maintenance requirements, and pressure losses in the piping. | Very high pressure |
| Explosion-Resistant Process Fan | 500–100,000 m³/h | 500–8,000 Pa | 50–75% | Configured for hazardous environments with appropriate material selection, electrical protection, grounding, and ignition-risk control. | Solvent exhaust, chemical processing, paint facilities, gas handling, battery production, and classified industrial areas. | Define the hazardous-area classification, gas or vapor group, temperature class, gas composition, temperature, and applicable local certification requirements. | Hazardous environments |